Bacterial contamination and antimicrobial susceptibility pattern of isolates from stethoscopes at a referral hospital in Tanzania

Authors

  • Elichilia R Shao Better Human Health Foundation, Mentorship&Coaching Institute, Imagedoctors international and Kilimanjaro Christian Medical Centre.
  • Nancy P Somi Medical Research Mbeya
  • Emmanuel G Kifato Sokoine University of Agriculture
  • Daniel W Gunda Department of medicine, Weill Bugando School of Medicine, 1464, Mwanza Tanzania
  • Semvua B Kilonzo Department of medicine, Weill Bugando School of Medicine, 1464, Mwanza Tanzania
  • Balthazar M Nyombi Kilimanjaro Christian Medical University College, Tumaini University Makumira PO BOX 2240 Moshi, Tanzania.

DOI:

https://doi.org/10.4314/tmj.v30i1.288

Abstract

Background

Nosocomial infections pose a challenge to the medical field and are a global safety issue for both patients and health care providers. In developing countries, the magnitude of the problem remains underestimated and literature is very scarce. Some nosocomial infections spread via contaminated medical equipment such as stethoscopes. No data reported from Tanzania about the potential role of stethoscopes in spreading these infections.

Methods

This cross-sectional study was conducted to determine bacterial contamination and antimicrobial susceptibility of isolates at Kilimanjaro Christian Medical Centre (KCMC) from February to April 2014. One hundred medical doctors and medical students were randomly selected to participate in this study. Structured questionnaires were used to collect demographic data and behavioural information related to the cleaning and storage of stethoscopes. Participants’ stethoscopes were sampled with sterile moistened cotton swabs. Laboratory analysis was done following standard microbiological techniques in the Microbiology Unit. Data analysis was done using SPSS window version 16, and p-values of <0.05 were considered statistically significant.

Results

A total of forty-six of the stethoscopes were found to be contaminated. A total of 134 bacterial strains were isolated. Of 134 isolates, 70 were potentially pathogenic, including S. aureus, Klebsiella ssp, Proteus ssp, E. coli and P. aeruginosa. Eighteen percent of the S. aureus were methicillin-resistant.

Conclusion

We found a significant amount of bacterial contamination of stethoscopes at our hospital, a significant percentage of which is Methicillin-Resistant Staphylococcus aureus (MRSA). Similar to other settings, in our setting in northern Tanzania, stethoscopes are important potential vehicles for nosocomial infections.

Key words: Nosocomial infections, stethoscopes, MRSA, Tanzania.

Author Biographies

  • Elichilia R Shao, Better Human Health Foundation, Mentorship&Coaching Institute, Imagedoctors international and Kilimanjaro Christian Medical Centre.
    Molecular Biologist and Physician in making- medical department KCMC Moshi Tanzania
  • Nancy P Somi, Medical Research Mbeya
    Reseach Scientist, at Mbeya Medical Research
  • Emmanuel G Kifato, Sokoine University of Agriculture
    Molecular Biology and Virology
  • Daniel W Gunda, Department of medicine, Weill Bugando School of Medicine, 1464, Mwanza Tanzania
    Internal Medicine
  • Semvua B Kilonzo, Department of medicine, Weill Bugando School of Medicine, 1464, Mwanza Tanzania
    Internal medicine
  • Balthazar M Nyombi, Kilimanjaro Christian Medical University College, Tumaini University Makumira PO BOX 2240 Moshi, Tanzania.
    Molecular Virology

References

Prevention of hospital-acquired infections: a practical guide. Geneva: World Health Organization; 2002

Burke JP. Infection control - a problem for patient safety. N Engl J Med 2003; 348: 651-6

Bates DW, Larizgoitia I, Prasopa-Plaizier N, Jha AK. Global priorities for patient safety research. BMJ 2009; 338

WHO guidelines on hand hygiene in health care. Geneva: World Health Organization; 2009.

Vincent JL, Rello J, Marshall J, Silva E, Anzueto A, Martin CD, et al., EPIC II Group of Investigators, et al. International study of the prevalence and outcomes of infection in intensive care units. JAMA 2009; 302: 2323-9.

Allegranzi B, Pittet D. Preventing infections acquired during health-care delivery. Lancet 2008; 372: 1719-20.

Uneke, C. J., Ogbonna, A., Oyibo, P. G., & Onu, C. M. (2010). Bacterial contamination of stethoscopes used by health workers: Journal of Infection in Developing Countries, 4(7), 436–441.

Uneke, C. J., Ogbonna, a, Oyibo, P. G., & Ekuma, U. (2008). Bacteriological assessment of stethoscopes used by medical students in Nigeria: implications for nosocomial infection control. World Health & Population, 10(4), 53–61.

G.Ducel, J.Fabry, L.Nicole,(2002)Prevention of Hospital Acquired Infections World Health Organization 72pp

Oie, S., Hosokawa, I., & Kamiya, A. (2002). Contamination of room door handles by methicillin Resistant Staphylococcus aureus, 140–143. Otto, M. (2012). MRSA virulence and spread. Cellular Microbiology, 14(10), 1513–21.

Pittet D, Allegranzi B, Sax H, Bertinato L, Concia E, Cookson B, et al., et al. Considerations for a WHO European strategy on health-care-associated infection, surveillance, and control. Lancet Infect Dis 2005; 5: 242-50

Report on the burden of health care-associated infection worldwide. Geneva: World Health Organization; 2010

Smith, M. A., Mathewson, J. J., Ulert, I. A., Scerpella, E. G., & Ericsson, C. D. (1996). contaminated stethoscopes revisted. Archives of Internal Medicine, 156, 82–84.

Zuliani Maluf, M. E., Maldonado, A. F., Bercial, M. E., & Pedroso, S. A. (2002). Stethoscope: a friend or an enemy? Sao Paulo Medical Journal = Revista Paulista de Medicina, 120(1), 13–15.

Allegranzi, B., Bagheri Nejad, S., Combescure, C., Graafmans, W., Attar, H., Donaldson, L., & Pittet, D. (2011). Burden of endemic health-care-associated infection in developing countries: systematic review and meta-analysis. Lancet, 377(9761), 228–241.

Jaballah N, Bouziri A, Mnif K, Hamdi A, KhaldiA, Kchaou W; Epidemiology of hospital-acquired bloodstream infections in a Tunisian pediatric intensive care unit: a 2-year prospective study. Am J Infect Control 2007, 35: 613-618.

Jroundi I, KhoudriI, Azzouzi A, Zeggwagh AA, Benbrahim NF, Hassouni F: Prevalence of Hospital-acquired infection in a Moroccan university hospital. Am J Infect Control 2007, 35 (6) 412-416.

2012, Clinical and Laboratory Standards Institute: Performance Standards for antimicrobial susceptibility testing; 22nd Informational supplement, vol 32, no3. M100-S22. Franklin RC. Clinical and laboratory standards Institute;2012.

Shiferaw, T., Beyene, G., Kassa, T., & Sewunet, T. (2013). Bacterial contamination, bacterial profile and antimicrobial susceptibility pattern of isolates from stethoscopes at Jimma University Specialized Hospital. Annals of Clinical Microbiology and Antimicrobials, 12, 39.

Africa-Purino FC, Dy ER,Coronel R: Stethoscopes: a potential source of nosocomial infections. Phil J Microbiol Infect Dis 2000, 29 (2) 9-13.

Kilic, I. H., Ozaslan, M., Karagoz, I. D., Zer, Y., Sava, E., & Davuto, V. (2011). The role of stethoscopes in the transmission of hospital infections, 10(30), 5769–5772.

Whittington M, WhitlowG, Hewson D, Thomas C, Brett S: Bacterial contamination of stethoscope on the intensive care unit. Anaesthesia 2009, 64: 620-624.

Schabrun S, Chipchase L: Healthcare equipment as a source of nosocomial infection: a systematic review. J Hosp Infect 2006, 63 (2): 239-245.

Marinella M, Pierson C,Chenoweth C; The stethoscope, a potential source of nosocomial infection. Arch Intern Med 1997, 15:786-790.

Nunez S, Moreno A,Green K, Villar J: The stethoscope in the emergency department: a vector of infection? J Epidemiol Infect 2000, 124: 233-237.

Gastmeier P, Schab F, Barwolf S, Ruden H, Grundmann H: Correlation between the genetic diversity of nosocomial pathogens and their survival time in intensive care units. J Hosp infect 2006, 62 (2) 181-186.

Parmar RC, Valvi CC, Sira P, Kamat J: A prospective randomized double-blind study of comparative efficacy of immediate versus daily cleaning of stethoscope using 66% ethyl alcohol. Indian J Med Sci 2004, 58 (10): 423-430.

Marcham C: Coats, ties, stethoscopes, cellphones, and ID badges: potential sources of healthcare-associated infections? Saf T Gram 2009, 16 (1): 1-4.

Genet C, Kibru G, Tsegaye W; Indoor air bacterial load and antibiotic susceptibility pattern of isolates in operating rooms and surgical wards at Jimma University specialized hospital, Southwest Ethiopia. Ethiop J Health Sci 2011, 21 (1): 9-17.

Fehr J, Hatz C, Soka I, Kibatala P, Urassa H, Smith T, et al., et al. Risk factors for surgical site infection in a Tanzanian district hospital: a challenge for the traditional National Nosocomial Infections Surveillance system index. Infect Control Hosp Epidemiol 2006; 27: 1401-4.

Eriksen HM, Chugulu S, Kondo S, Lingaas E. Surgical-site infections at Kilimanjaro Christian Medical Center. J Hosp Infect 2003; 55: 14-20.

United Republic of Tanzania, T. H. E., Of, R., & Health, M. O. F. (2004). The United Republic Of Tanzania National Infec tion Prevention And Control Guidelines FoR Tanzanian Ministry of Health, (July), 1–130

Moyo SJ,Aboud S, Blomberg B,Mkopi N, Kasubi M,Manji K,Lyamuya EF, Maselle SY, Langeland N. High nasal carriage of methicillin-resistant Staphylococcus aureus among healthy Tanzanian under-5 children. Microb Drug Resist.2014; 20 (1): 82-8.

Downloads

Published

2019-09-24

Issue

Section

Original Research

How to Cite

Bacterial contamination and antimicrobial susceptibility pattern of isolates from stethoscopes at a referral hospital in Tanzania. (2019). Tanzania Medical Journal, 30(1), 37-52. https://doi.org/10.4314/tmj.v30i1.288

Most read articles by the same author(s)